Toyota 5S-FE cylinder head flow test – After light port & polishing

 

March 13, 2003

 

Flow testing: 28” H2O

 

Custom made Ferrea valves:

Intake valves: 33mm (head diameter) X 97.5mm (stem length) with a 6mm diameter stem

Exhaust valves: 28mm (head diameter) X 98.5mm (stem length) with a 6mm diameter stem

 

Intake: 1.300” head diameter             6mm stem

Light port work, seats machined with 5 angles

45º Seat

¾” radius inlet

 

Valve Lift

Setting1

%2

Flow (CFM)

Gain (CFM)

.100”

199

46.5

83.58

8.95

.200”

199

86

157.21

13.93

.300”

296

70.5

180.56

28.12

.400”

296

72.5

183.52

31.08

 

Exhaust: 1.100” head diameter           6mm stem

Light port work, 3 angles & radius on seat

45º Seat

 

Valve Lift

Setting1

%2

Flow (CFM)

Gain (CFM)

.100”

106

63

66.78

2.12

.200”

208

55

114.40

6.24

.300”

208

66.5

138.32

13.52

.400”

208

70

145.60

18.72

 

Notes:

1    The setting value refers to the maximum flow setting on the flow test machine